| Search: |
|
|
|
SCM202 AC Voltage to 4-20mA Converter |
(Up) |
|
|
The SCM202 measures AC voltage in the 0-500V range and converts it into a 4-20mA Current Loop signal. The unit also features galvanic isolation on both the input and output sides, and test points for monitoring the current loop without interrupting it. |
|
|
|
Technical Specifications
Accuracy |
±0.1% over full range, typical (for 2-100%) for sinusoidal input |
Temperature stability |
±0.02%/°C |
Response time |
220 ms (0-98%) |
Output voltage ripple |
0.1% of full range RMS |
Frequency range |
40-500Hz |
Galvanic isolation |
2.5KV RMS in 1 minute |
Loop power supply |
10-32VDCc |
Output current |
4-20mA |
Test tap |
40-200mV represents 4-20mA (shunt 10ohm ±1%) |
Output over-voltage protection |
33V tranzorb |
Output over-current protection |
slow fuse 100mA 20x5mm |
Current loop resistance |
Rmax(ohms)=(Vsupply-10)/0.02 |
Zero adjustment |
±25% min |
Span adjustment |
±25% min |
Operating temp. range |
0-70°C without condensation |
Storage temp. range |
-25 to 85°C |
Enclosure |
plastic 35x89x71mm, IP50 |
Mounting |
standard 35mm rail |
|
|