An Uninterruptible Power Supply (UPS) is an electrical apparatus which provides backup power to a load when the normal power source fails. This UPS will provide near instantaneous protection from power interruptions, by using energy that is stored in a battery to substitute the normal supply. This UPS can be supplied either with or without a 7Ah or 9Ah 12V battery (these batteries are the same type used in alarm systems and are available from most electronics stores - easily interchangeable/replaceable if necessary), providing an average of 20 or 30 minutes back-up supply to one PC.
This UPS also provides surge protection - on an unstable power grid, interruptions or load shedding, as well as lightning strikes, can cause spikes which may result in damage to equipment. This UPS has lightning/surge protection up to 175 Joules.
The units are supplied with a power supply cable for the UPS, as well as two cables for supplying equipment with power from the UPS. A legacy RS232 serial cable is also included in the package.
Lead-time of approximately 1-3 days on additional stock, approximately 40 units in stock with supplier. |
|
|
|
Technical Specifications
Model |
Name |
IDEAL-5708C |
Capacity |
800VA / 480W |
Input |
Voltage |
220V/230/240Vac |
Voltage Range |
-30% / +25% |
Frequency |
50Hz or 60Hz (Auto-Sensing) |
Output |
Voltage Regulation AC Mode |
±10% |
Voltage Regulation Battery Normal |
±10% |
Frequency |
50Hz or 60Hz ±1Hz |
Waveform |
Simulated Sinewave |
Transfer Time |
<6ms (Typical) |
Outlets: IEC-320 |
4/4 |
Outlets: Universal |
2 |
Battery |
Voltage |
12VDC |
Type |
12V / 7AH |
Recharge Time |
5hrs to 90% after complete discharge |
Safety Protection |
Over Charge & Over Discharge Protection |
Advanced Battery Management |
Yes |
Back-up Time (1 PC) |
20 minutes |
Display |
LED Status Indicators |
Normal (Green), Battery (Yellow), UPS cut off (Red) |
Audible Alarm |
Battery Mode |
Two short tones every 8 seconds |
Low Battery |
Four short tones every second |
Overload |
Red LED: Flashing, Buzzer: Beeping continuously |
Fault |
Beeping continuously |
Features |
AVR (Automatic Voltage Regulation) |
2 Boost + 1 Buck |
Modem/Phone Protection |
RJ-11 Port |
DC Start Function |
Yes |
Over/Under Voltage Protection |
Yes |
No-load Cut-off (Green Mode) |
Yes |
Silence The Audible Alarm |
Yes |
Off-Mode Charging |
Yes |
Short Circuit Protection |
AC Fuse and Electronic Circuit (Line Mode) |
Lightning/Surge Protection |
175 Joules (220/230/240Vac) |
Management |
Communications Port |
RS232 COM Port |
Software |
Auto-Shutdown Software |
Enviroment |
Operating Temperature |
0° C - 40° C |
Humidty |
0-95% (Non-Condensing) |
Acoustic Noise |
<40 dB at 1m |
Safety Standards |
LVD |
CE (EN60950-1:2006+A11:2009+A1:2010+A12:2011) |
EMC |
CE (EN55022:2010 ; EN55024:2010) |
Size |
Dimensions (W*D*H) |
305*98*170mm |
Quality Assurance |
System |
ISO9001-2008 |
|
|